Pre-Measured Flux Gains#
This section provides pre-measured flux gains derived from Liu et al. (2024). The data were collected under the following reference conditions:
Ambient Temperature: 15 degrees Celsius
Zenith Angle: 10.15 degrees
Corrections for temperature and zenith angle are necessary if your observation conditions differ.
Data#
The data are available in HDF5 format at This link and include the following:
Ambient_Temperature: Ambient temperature (°C)
ZA: Zenith angle (°)
freq: Frequency sample (MHz)
K_Jy1…K_Jy19: Flux gain (K/Jy)
err_K_Jy1…err_K_Jy19: Flux gain error
Usage#
Method 1: Simplified Approach
Use the hifast.flux function (version >= 1.3a3), which automatically handles ambient temperature and zenith angle corrections.
Method 2: Manual Correction
Read the flux gain data from the HDF5 file.
Apply the appropriate corrections for your specific observation conditions.
The following example shows the basic procedure.